 Power Entry Modules with Line Filter www.schurter.com/pg06 IEC Appliance Inlet C20 with Filter, Circuit Breaker TA45 (recessed)
EF2
Standard- or Medical-Filter
C20
70 C
Description
-PanelMount: Screw-onmountingfromfrontside -3Functions: ApplianceInletProtectionclassI,circuitbreakertypeTA452pole,Linefilterinstandardandmedicalversion -Quickconnectterminals6.3x0.8mm -Alternative:versionwithoutlinefilterEF11
Characteristics
-Allsingleelementsarealreadywired -Lineswitchnon-illuminated Illuminatedversiononrequest Thermaloverloadprotection Optionalwithundervoltage-orremotetriprelease -WithEMC-shield -QualifiedforuseinequipmentaccordingIEC/EN60950
Approvals
References Weblinks
-VDELicenseNumber:40001520 -ULLicenseNumber:E72928
GeneralProductInformation Approvals,RoHS,CHINA-RoHS,MatingConnectors,e-Store, Distributor-Stock-Check,Accessories
Technical Data
RatingsIEC RatingsUL/CSA LeakageCurrent DielectricStrength 12-16A@Ta40C/250VAC;50Hz 12-20A@Ta40C/125VAC;60Hz standard<0.5mA(250V/60Hz) medical<5A(250V/60Hz) >1.7kVDCbetweenL-N >2.7kVDCbetweenL/N-PE Testvoltage(2sec) -10Cto55C 10/055/21acc.toIEC60068-1 fromfrontsideIP40acc.toIEC60529 Suitableforapplianceswithprotection class1acc.toIEC61140 Quickconnectterminals6.3x0.8mm Screw:max8mm Mountingscrewtorquemax0.5Nm Thermoplastic,black,UL94V-0 Appliance-Inlet/-Outlet C20acc.toIEC/EN60320-1, UL498,CSAC22.2no.42(forcold conditions)pin-temperature70C,16A, ProtectionClass1 Acc.IEC/EN60934,UL1077,CSA 22.2no.235 2-polerockerswitch,illuminatedornonilluminated.Optionalwithundervoltage- orremotetriprelease ShortcircuitcapacityIcn: atIn<3A/240VAC:10xIn atIn3A/240VAC:300A Rockerswitch2-pole,non-illuminated orilluminated,acc.toIEC61058-1 Technicaldetails StandardandMedicalVersion,IEC 60939,IEC60601-1,UL1283,UL544, EN133200,CSAC22.2no.8 Technicaldetails >100'000hacc.toMIL-HB-217F
CircuitBreakers
AllowableOperationTemp. ClimaticCategory DegreeofProtection ProtectionClass Terminal PanelThicknesss Material:Housing
LineSwitch
LineFilter
MTBF
EMC Products
EF2
www.schurter.com/pg06 Dimensions
37 32.2 10.6 76.2* 41.2 0.8
R 05 3.
Power Entry Modules with Line Filter
59.5mm
2.8 32.9 3.6
90 0.10
R
3. 55
0 .0 5
40.55
79.2
40.55
80.05
10.9
R 2.8
4. 7
12.55
12.2
3.3 6.4 9.5 59.5
S 5.3
33.9 0.10
* --- Version TA45 with undervoltage release
Technical Data of Filter-Components
Rated Current [A] 12 16 20 12 16 20 Filter-Type Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances L [mH] 2 x 0.8 2 x 0.6 2 x 0.3 2 x 0.8 2 x 0.6 2 x 0.3 Capacitance CX [nF] 100 100 100 100 100 100 Capacitance CY [nF] 2.2 2.2 2.2 R [M] 1 1 1 1 1 1
Diagrams Standard version
Medical version
1) Line 2) Load
1) Line 2) Load ----differentialmode_____commonmode
Attenuation Loss 12 A
Standardversion
16 A
20 A
2
EMC Products
4.55 0.05
R
5.5
R6
.5
810.10
101
90
Power Entry Modules with Line Filter www.schurter.com/pg06
Medicalversion(M5)
EF2
20 A
12 A
16 A
EMC Products
EF2
www.schurter.com/pg06
Power Entry Modules with Line Filter
EMC Products
Power Entry Modules with Line Filter www.schurter.com/pg06 Packaging unit Accessories
Description
EF2
16Pcs
Assorted Covers Rear Cover 0859.0109
Cord retaining kits Cord retaining strain relief Flat head, Z Flat head, H 0888.0021 4700.0008
Mating Outlets/Connectors
Category / Description Connector Overview complete IEC Connector C19, Rewireable, Straight IEC Connector C19, Rewireable, Angled IEC Connector C19, Rewireable, Straight IEC Connector C19, Rewireable, Angled IEC Connector C19, Rewireable, Straight Connector further types to EF12 0104 1651 1652 4790 4795
Power Cord Overview complete Power Cord with IEC Connector C19, Straight Power Cord further types to EF12 1654
Power Supply or Interconnection Cord Overview complete Divers Power Supply and Interconnection Cords 16 A Power Supply or Interconnection Cord further types to EF12 Kabelverbindung/16 A
EMC Products
EF2
www.schurter.com/pg06
Technical data (continued) Circuit breaker Tripping characteristics In < 3 A
[ min ] [ sec ] 10'000
Power Entry Modules with Line Filter
Tripping characteristics In 3... < 18 A
[ min ] [ sec ] 10'000
Tripping characteristics In 18 A
min ] [ sec ] 10'000
Type Rated current
TA45 In <3 A 1 pole protected
Type Rated current
TA4 5 In 3 A... < 18 A 1 pole protected 2 pole protected
Type Rated current
TA4 5 In 18 A 1 pole protected
60 30 20 10 5 200 100 1 50 20 10 5 2 1 0,5 2000 1000 500
60 30 20 10 5 200 100 1 50 20 10 5 2 1 0,5 Tripping time 0,3 0,2 0,1 1,05 1,32 2 2000 1000 500
0 0 0 0 5 200 100 1 50 20 10 5 2 1 0,5 Tripping time 0,3 0,2 0,1 1,05 1,32 2 2000
2 pole protected
2 pole protected
1000 500
Ambient temp. +23 C
Ambient temp.
+23 C
Ambient temp.
+23 C
Tripping time
0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 10 [ x In ]
3
4
5
8
10
3
4
5
8
10
Multiple of rated current
Multiple of rated current
[ x In ]
Multiple of rated current
[ x In ]
1) Effect of ambient temperature The unit is calibrated for an ambient temperature of +23 C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table on the right side:
* Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached. Example Rated current at +23 C Ambient temperature Correction factor Chosen rated current at +40 C ambient temperature
1)
* Ambient temperature [C] -10 -5 0 +23 +30 +40 +55
Correction factor 0,89 0,91 0,92 1,00 1,03 1,08 1,16
6,0 A +40 C 1,08 6 A x 1,08 = 6,5 A
Order code for EF12 (order example) Type Order code TA45 (2-pole rocker-switch without accessories) Please note that Schurter will establish an internal new part number for logistical use in addition to the order code. The format of this internal part number is, for example EF12.xxxx.1110.01 Application note The rated current of the line filter must be equal or higher than the rated current of the circuit-breaker Other versions on request - Rocker switch illuminated Wiring 1 = wired Protection class 0 = Class I, housing black Panel mount 0 = Screw-on version Terminals 1 = Quick connect terminals 6,3 x 0,8 mm Line filter version 1 = standard 2 = medical Line filter, rated current 1 = 20 A, 2 = 16 A, 3 = 12 A
Thespecifications,descriptionsandillustrationsindicatedinthisdocumentarebasedon EMC Products currentinformation.Allcontentissubjecttomodificationsandamendments.
EF12.
A B T W F 1 5 0 C 0. see table 1
11 1 0. 0 1
6


▲Up To Search▲   

 
Price & Availability of EF12ABTWF150C0221001

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X